How to Use This Guide
®
Use this guide to quickly set up your Enterasys
 B5 switch. 
Enterasys Networks recommends that you refer to the Enterasys 
B5 Gigabit Ethernet Switch Hardware Installation Guide for 
specifications and safety warnings. 
The latest B5 documentation is located at 
www.enterasys.com/support/manuals.
Hardware Components
The following figures show the several types of front panel port 
and rear panel connections on your B5 switch. 
Figure 1
B5 Switch Front Panels
B5G124-24, B5G124-24P2
B5G124-48, B5G124-48P2
B5K125-24, B5K125-24P2
B5K125-48, B5K125-48P2
Figure 2
B5 Switch Back Panels
Non-PoE B5 Switches
PoE B5 Switches
Key
1
Switch status LEDs
8
Console port
2
RJ45 10/100/1000 Mbps ports
9
Stack connection ports
3
SFP slots
10
Rotary switch
4
10G slots
11
Password reset button
RJ45 status LEDs
AC power input connector
5
12
6
SFP port status LEDs
13
Redundant power supply
7
10G port status LEDs
(RPS) connector
Handling the Switch
Caution: The switch can be damaged by electrostatic discharge.
To prevent electrostatic damage, attach an electrostatic discharge 
(ESD) wrist strap to your wrist before handling the switch.
Unpack the switch as follows:
1. Remove the packing material protecting the switch.
2. Remove the tape seal on the non‐conductive bag to remove the 
switch.
3. Perform a visual inspection of the switch for any signs of 
physical damage. Contact Enterasys Networks if there are any 
signs of damage. See "Getting Help" for more information on 
contacting Enterasys Networks. 
Stacking Switches
Up to eight B5 switches can be stacked together and connected by 
high‐speed stacking cables, which allow the entire stack to operate 
with a single IP address.
The B5 supports the following high‐speed stacking cables only, 
which you must order separately:
• STK‐CAB‐SHORT
• STK‐CAB‐LONG
• STK‐CAB‐2M
• STK‐CAB‐5M
Note: You can stack a B5 switch only with other B5 switches.
For complete information about stacking, refer to the Enterasys B5 
Gigabit Ethernet Switch Hardware Installation Guide.
Connecting Power to the Switch
Electrical Hazard: Only qualified personnel should perform
installation procedures.
You can connect to a single, primary source of power, or to two 
sources of power for redundancy. The example used here 
describes connecting to two power sources.
The following redundant power supplies are available to be 
purchased from Enterasys Networks for connection to a B5 
switch:
• STK‐RPS‐150PS, a 102‐156 watt DC power supply capable of 
providing power to a fully‐loaded non‐PoE switch.
• STK‐RPS‐500PS, a 500 watt DC power supply recommended 
for full PoE capability.
To power‐up your B5 switch:
1. Attach the power cord from your redundant power supply 
into the B5 switch's redundant power receptacle.
2. Attach the AC power cord to the B5 switch's AC power 
receptacle.
3. Plug the redundant power supply and the B5 switch AC 
power cords into dedicated, grounded AC outlets.
4. Once power is connected, verify that the CPU (system) LED 
turns amber until the B5 switch finishes its initialization.
If the initialization process is successful, the CPU LED turns green. 
If the CPU LED does not turn green, refer to the Enterasys B5 
Gigabit Ethernet Switch Hardware Installation Guide for 
troubleshooting information. 
Completing Switch Setup and Downloading the Latest
Firmware
Once you have connected power to the B5 switch and verified 
LED activity, you can complete the setup process as follows. Refer 
to the Enterasys B5 Gigabit Ethernet Switch Hardware Installation 
Guide for more information.
1. Determine the latest B5 firmware version by visiting the 
Enterasys Networks download site at:
http://secure.enterasys.com/services/support/downloads/software
2. Connect the switch to the network.
3. Connect a management station to the console port.
4. Verify that the network devices connected to the switch ports 
are powered on, and that each link/activity LED is on (solid 
green or blinking green).
5. At the device connected to the console port, perform the 
following:
a. Enter admin for Username.
b. At the Password prompt, press ENTER (RETURN). 
c. At the command prompt, determine if the latest firmware 
image is loaded on the switch by entering this command:
show version
d. If the output (under FW Version) displays an older version 
number than that determined in step 1, download and 
activate the new version as directed on the download 
website. (Alternatively, you can use the CLI commands 
listed in Table
1.)
Basic Setup Commands
Table
1 lists CLI commands that are required for setting up the B5 
switch with the latest firmware. Table
2 lists additional 
configuration commands for your B5 switch. For the complete list 
of CLI commands, see the Enterasys B5 CLI Reference.
Table 1 Required CLI Setup Commands
Step Task
CLI commands
1
Set a new password
set password [username]
2
Set the switch IP address
set ip address ip-address
[mask ip-mask] [gateway
ip-gateway]
3
Download, activate, and
copy
verify new firmware on the
tftp:
//
tftp_server_ip_address
filename system:image
switch using TFTP copy
set boot system filename
Note: You can reboot the
show version
system immediately with the
set boot system
command, or reboot later
with the
command.
reset
Table 2 Optional CLI Setup Commands
Task
CLI commands
Save the active configuration
save config
Enable or disable SSH
set ssh enable | disable
Enable or disable Telnet
set telnet {enable | disable}
[inbound | outbound | all]
Enable or disable HTTP
set webview {enable | disable}
management (WebView)
Enable or disable SNMP port link
set port trap port-string
traps
{enable | disable}
Set the per port broadcast limit
set port broadcast port-string
threshold-value
Configure a VLAN
set vlan create vlan-id
set port vlan port-string
vlan-id modify-egress
Set a Syslog server IP and severity
set logging server index
ip-addr ip-addr severity
severity state enable
Table 2 Optional CLI Setup Commands (Continued)
Task
CLI commands
Configure and enable a RADIUS
set radius server index
server
ip-addr port [secret-value]
{realm {management-access |
any | network-access}
set radius enable
Specifications
For a complete list of specifications, see the Enterasys B5 Gigabit 
Ethernet Switch Hardware Installation Guide. 
Interfaces
Table 3 B5 Interface Descriptions
B5G124-24
• 24 10/100/1000Base-T ports
• Four combo SFP ports
B5G124-24P2
• 24 10/100/1000Base-T 802.3af and 802.3at
PoE-capable ports
• Four combo SFP ports
B5G124-48
• 48 10/100/1000Base-T ports
• Four combo SFP ports
B5G124-48P2
• 48 10/100/1000Base-T 802.3af and 802.3at
PoE-capable ports
• Four combo SFP ports
B5K125-24
• 24 10/100/1000Base-T ports
• Two combo SFP ports
• Two 10G ports
B5K125-24P2
• 24 10/100/1000Base-T 802.3af and 802.3at
PoE-capable ports
• Two combo SFP ports
• Two 10G ports
B5K125-48
• 48 10/100/1000Base-T ports
• Two combo SFP ports
• Two 10G ports
B5K125-48P2
• 48 10/100/1000Base-T 802.3af and 802.3at
PoE-capable ports
• Two combo SFP ports
• Two 10G ports
/
Switch Dimensions
Size:
44.1 W x 4.4 H x 36.85 D cm
17.4 W x 1.7 H x 14.5 D in
Power Consumption
Input Voltage: 100 to 240VAC
Temperature and Humidity
Operating temperature: 0°C to 50°C
Storage temperature: ‐40°C to +70°C
Operating relative humidity: 5% to 95%
Getting Help
World Wide Web
www.enterasys.com/support/
Phone
1-800-872-8440 (toll-free in U.S. and Canada)
or 1-978-684-1888
To find the Enterasys Networks Support toll-free
number in your country:
www.enterasys.com/services/support/contact/
Internet mail
support@enterasys.com
To expedite your message, type [Switching] in the
subject field of your message.
Latest image and
www.enterasys.com/services/support/downloads/
release notes
software/

Advertisement

loading

Summary of Contents for Enterasys B5G124-24P2

  • Page 1 Stack connection ports management (WebView) or 1-978-684-1888 turns amber until the B5 switch finishes its initialization. SFP slots Rotary switch Enable or disable SNMP port link To find the Enterasys Networks Support toll-free set port trap port-string 10G slots Password reset button If the initialization process is successful, the CPU LED turns green.  traps {enable | disable} number in your country:...
  • Page 2 EN 60950‐1:2006 interference in which case the user may be required to take adequate measures.  EN 60825‐1:2007 This table shows where these substances may be found in the supply chain of Enterasys’ electronic EN 60825‐2:2004 Clase A. Aviso de ITE information products, as of the date of sale of the enclosed product. Note that some of the component types Equipment Type/Environment: Information Technology Equipment, ...