Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense. WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Industry Canada Notice This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. Class A ITE Notice WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Clase A. Aviso de ITE ADVERTENCIA: Este es un producto de Clase A. En un ambiente doméstico este producto puede causar ...
This product complies with the following: 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000‐3‐2, EN 61000‐3‐3, EN 55024, AS/NZS CISPR 22, VCCI V‐3. Este producto de Enterasys cumple con lo siguiente: 47 CFR Partes 2 y 15, CSA C108.8, 89/336/EEC, EN 55022, EN 55024, EN 61000‐3‐2, EN 61000‐3‐3, AS/NZS CISPR 22, VCCI V‐3. Dieses Produkt entspricht den folgenden Richtlinien: 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000‐3‐2, EN 61000‐3‐3, EN 55024, AS/NZS CISPR 22, VCCI V‐3. This product complies with the requirements of European Directive, 2002/95/EC, Restriction of Hazardous Substances (RoHS) in Electrical and Electronic Equipment. European Waste Electrical and Electronic Equipment (WEEE) Notice In accordance with Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment (WEEE): The symbol above indicates that separate collection of electrical and electronic equipment is required and that this product was placed on the European market after August 13, 2005, the date of enforcement for Directive 2002/96/EC. When this product has reached the end of its serviceable life, it cannot be disposed of as unsorted municipal waste. It must be collected and treated separately. It has been determined by the European Parliament that there are potential negative effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment. It is the users’ responsibility to utilize the available collection system to ensure WEEE is properly treated. For information about the available collection system, please go to http://www.enterasys.com/services/support/ or contact Enterasys Customer Support at 353 61 705586 (Ireland). Electromagnetic Compatibility (EMC) Compatibilidad Electromágnetica (EMC) Elektro- magnetische Kompatibilität ( EMC ) Hazardous Substances...
Page 6
VCCI Notice This is a class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. BSMI EMC Statement — Taiwan This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Application of Council Directive(s): Manufacturer’s Name: Manufacturer’s Address: European Representative Address: Conformance to Directive(s)/Product Standards: Equipment Type/Environment: Enterasys Networks, Inc. declares that the equipment packaged with this notice conforms to the above directives. Enterasys Networks warrants to the original consumer or purchaser that each of its products, and all components thereof, will be free from defects in material and/or workmanship for a period of one year from the original factory shipment date. Any warranty hereunder is extended to the original consumer or purchaser and is not assignable. Enterasys Networks makes no express or implied warranties including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose, except as expressly set forth in this warranty. In no event shall Enterasys Networks be liable for incidental or consequential damages, costs, or expenses arising out of or in connection with the performance of the product delivered hereunder. Enterasys Networks will in no case cover damages arising out of the product being used in a negligent fashion or manner. NOTE: Enterasys Networks reserves the right to change specifications without notice. Please contact your representative to confirm current specifications. Declaration of Conformity 89/336/EEC 73/23/EEC Enterasys Networks, Inc. 50 Minuteman Road Andover, MA 01810 Enterasys Networks, Ltd. Nexus House, Newbury Business Park London Road, Newbury Berkshire RG14 2PZ, England EC Directive 89/336/EEC EN 55022 EN 61000‐3‐2 EN 61000‐3‐3 EN 55024 EC Directive 73/23/EEC EN 60950...
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc. on behalf of itself and its Affiliates (as hereinafter defined) (“Enterasys”) that sets forth Your rights and obligations with respect to the Enterasys software program/firmware installed on the Enterasys product (including any accompanying documentation, hardware or media) (“Program”) in the package and prevails over any additional, conflicting or inconsistent terms and conditions appearing on any purchase order or other document submitted by You. “Affiliate” means any person, partnership, corporation, limited liability company, or other form of enterprise that directly or indirectly through one or more intermediaries, controls, or is controlled by, or is under common control with the party specified. This Agreement constitutes the entire understanding between the parties, and supersedes all prior discussions, representations, understandings or agreements, whether oral or in writing, between the parties with respect to the subject matter of this Agreement. The Program may be contained in firmware, chips or other media. BY INSTALLING OR OTHERWISE USING THE PROGRAM, YOU REPRESENT THAT YOU ARE AUTHORIZED TO ACCEPT THESE TERMS ON BEHALF OF THE END USER (IF THE END USER IS AN ENTITY ON WHOSE BEHALF YOU ARE AUTHORIZED TO ACT, “YOU” AND “YOUR” SHALL BE DEEMED TO REFER TO SUCH ENTITY) AND THAT YOU AGREE THAT YOU ARE BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES, AMONG OTHER PROVISIONS, THE LICENSE, THE DISCLAIMER OF WARRANTY AND THE LIMITATION OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT OR ARE NOT AUTHORIZED TO ENTER INTO THIS AGREEMENT, ENTERASYS IS UNWILLING TO LICENSE THE PROGRAM TO YOU AND YOU AGREE TO RETURN THE UNOPENED PRODUCT TO ENTERASYS OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL REFUND. IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT ENTERASYS NETWORKS, LEGAL DEPARTMENT AT (978) 684‐1000. You and Enterasys agree as follows: LICENSE. You have the non‐exclusive and non‐transferable right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this Agreement. RESTRICTIONS. Except as otherwise authorized in writing by Enterasys, You may not, nor may You permit any third party to: (i) Reverse engineer, decompile, disassemble or modify the Program, in whole or in part, including for reasons ...
Page 9
APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and federal courts of the Commonwealth of Massachusetts without regard to its conflicts of laws provisions. You accept the personal jurisdiction and venue of the Commonwealth of Massachusetts courts. None of the 1980 United Nations Convention on Contracts for the International Sale of Goods, the United Nations Convention on the Limitation Period in the International Sale of Goods, and the Uniform Computer Information Transactions Act shall apply to this Agreement. EXPORT RESTRICTIONS. You understand that Enterasys and its Affiliates are subject to regulation by agencies of the U.S. Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain technical products to certain countries, unless a license to export the Program is obtained from the U.S. Government or an exception from obtaining such license may be relied upon by the exporting party. If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes. If the Program is exported from the United States pursuant to the License Exception TSR under the U.S. Export Administration Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, You agree not to (i) reexport or release the Program, the source code for the Program or technology to a national of a country in Country Groups D:1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia, Iraq, Kazakhstan, Kyrgyzstan, Laos, Latvia, Libya, Lithuania, Moldova, North Korea, the People’s Republic of China, Romania, Russia, Rwanda, Tajikistan, Turkmenistan, Ukraine, Uzbekistan, Vietnam, or such other countries as may be designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the direct product of the Program or the technology, if such foreign produced direct product is subject to national security controls as identified on the U.S. Commerce Control List, or (iii) if the direct product of the technology is a complete plant or any major component of a plant, export to Country Groups D:1 or E:2 the direct product of the plant or a major component thereof, if such foreign produced direct product is subject to national security controls as identified on the U.S. Commerce Control List or is subject to State Department controls under the U.S. Munitions List. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Program (i) was developed solely at private expense; (ii) contains “restricted computer software” submitted with restricted rights in accordance with section 52.227‐19 (a) through (d) of the Commercial Computer Software‐Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Enterasys and/or its suppliers. For Department of Defense units, the Program is considered commercial computer software in accordance with DFARS section 227.7202‐3 and its successors, and use, duplication, or disclosure by the Government is subject to restrictions set forth herein. DISCLAIMER OF WARRANTY. EXCEPT FOR THOSE WARRANTIES EXPRESSLY PROVIDED TO YOU IN WRITING BY ENTERASYS, ENTERASYS DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE AND NON‐ INFRINGEMENT WITH RESPECT TO THE PROGRAM. IF IMPLIED WARRANTIES MAY NOT BE DISCLAIMED BY APPLICABLE LAW, THEN ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THIRTY (30) DAYS AFTER DELIVERY OF THE PROGRAM TO ...
Page 10
AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical value to Enterasys and, accordingly, You hereby agree to maintain complete books, records and accounts showing (i) license fees due and paid, and (ii) the use, copying and deployment of the Program. You also grant to Enterasys and its authorized representatives, upon reasonable notice, the right to audit and examine during Your normal business hours, Your books, records, accounts and hardware devices upon which the Program may be deployed to verify compliance with this Agreement, including the verification of the license fees due and paid Enterasys and the use, copying and deployment of the Program. Enterasys’ right of examination shall be exercised reasonably, in good faith and in a manner calculated to not unreasonably interfere with Your business. In the event such audit discovers non‐compliance with this Agreement, including copies of the Program made, used or deployed in breach of this Agreement, You shall promptly pay to Enterasys the appropriate license fees. Enterasys reserves the right, to be exercised in its sole discretion and without prior notice, to terminate this license, effective immediately, for failure to comply with this Agreement. Upon any such termination, You shall immediately cease all use of the Program and shall return to Enterasys the Program and all copies of the Program. OWNERSHIP. This is a license agreement and not an agreement for sale. You acknowledge and agree that the Program constitutes trade secrets and/or copyrighted material of Enterasys and/or its suppliers. You agree to implement reasonable security measures to protect such trade secrets and copyrighted material. All right, title and interest in and to the Program shall remain with Enterasys and/or its suppliers. All rights not specifically granted to You shall be reserved to Enterasys. 10. ENFORCEMENT. You acknowledge and agree that any breach of Sections 2, 4, or 9 of this Agreement by You may cause Enterasys irreparable damage for which recovery of money damages would be inadequate, and that Enterasys may be entitled to seek timely injunctive relief to protect Enterasys’ rights under this Agreement in addition to any and all remedies available at law. 11. ASSIGNMENT. You may not assign, transfer or sublicense this Agreement or any of Your rights or obligations under this Agreement, except that You may assign this Agreement to any person or entity which acquires substantially all of Your stock or assets. Enterasys may assign this Agreement in its sole discretion. This Agreement shall be binding upon and inure to the benefit of the parties, their legal representatives, permitted transferees, successors and assigns as permitted by this Agreement. Any attempted assignment, transfer or sublicense in violation of the terms of this Agreement shall be void and a breach of this Agreement. 12. WAIVER. A waiver by Enterasys of a breach of any of the terms and conditions of this Agreement must be in writing and will not be construed as a waiver of any subsequent breach of such term or condition. Enterasys’ failure to ...
About This Guide Purpose ... xi Who Should Use This Guide ... xi Document Conventions ... xii Getting Help ... xii Chapter 1: Introduction Functions and Features ...1-1 Port Indicators ...1-1 Chapter 2: Installation and Connection Verifying the Kit ...2-1 Kit Contents ...2-2 Technical Considerations ...2-3 Configuration for a Mid-Span Power Hub ...2-3...
Purpose This guide provides information and procedures on hardware installation, setup, configuration, and management of the Enterasys Networks 8‐port and 24‐port Mid‐Span Power Hubs. Note: This guide applies to the following products: • BL-69108ENT, which is a standalone 8-port chassis • BL-69524ENT, which is the chassis complete with three eight-port modules • BL-69224ENT, which is the chassis without modules Who Should Use This Guide Electrical Hazard: Only qualified personnel should perform installation procedures.
• Your Enterasys Networks service contract number • A description of the failure xii About This Guide www.enterasys.com/services/support/ 1-800-872-8440 (toll-free in U.S. and Canada) or 1-978-684-1000 For the Enterasys Networks Support toll-free number in your country: www.enterasys.com/services/support/contact/ support@enterasys.com To expedite your message, type [other] in the subject line.
Page 15
• A description of any action(s) already taken to resolve the problem (for example, changing mode switches or rebooting the unit) • The serial and revision numbers of all involved Enterasys Networks products in the network • A description of your network environment (for example, layout or cable type) • Network load and frame size at the time of trouble (if known) • The device history (for example, have you returned the device before or is this a recurring problem) • Any previous Return Material Authorization (RMA) numbers Getting Help Mid-Span Power Hub User’s Guide xiii...
Functions and Features The BL‐69108ENT and BL‐69524ENT, Enterasys Networks’ 8‐port and 24‐port Mid‐Span Power Hubs, support applications in which AC power is difficult to access, such as VoIP phones, wireless LAN access points, or IP network cameras. The Enterasys Mid‐Span Power Hubs act as “patch panels” and add ~48 VDC to unused (non‐data) wires in standard Category 5, 5e, or 6 Ethernet cable. The power unit delivers both data and power over a single standard Ethernet cable. Main features of the Mid‐Span Power Hubs: • Fully hot‐swappable module banks • Remote power feeding; powered devices receive power over the Ethernet cable • Centralized power distribution; one powered device can be connected to a single in‐line unit • IEEE 802.3af standard powering scheme • Act as normal patch panels and place ~48 VDC on unused Ethernet pins • Total power available: 15.6 W per port per IEEE specification • Automatic power‐control circuitry to detect a powered device before providing power • Fused power surge protection Port Indicators Each port has its own LEDs, which display the following: • Detect/Power Forwarding (blue) • Power from Chassis (green) For information on Troubleshooting, refer to Table Introduction 3‐1 on page 3‐1.
Riesgo Eléctrico: Solamente personal capacitado debe de instalar o darle servicio a esta unida. Elektrischer Gefahrenhinweis: Installationen oder Servicearbeiten sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden. Verifying the Kit Unpack the unit and verify that you have all of the following items (see Figure • Enterasys Networks 8‐port or 24‐port Mid‐Span Power Hub • Power Cord • User’s Guide Installation and Connection Mid-Span Power Hub User’s Guide 2-1...
Kit Contents Kit Contents Figure 2-1 Figure 2-2 2-2 Installation and Connection Contents of the BL-69108ENT Kit BL-69108ENT 8-Port Mid-Span Power Hub Contents of the BL-69524ENT Kit BL-69524ENT 24-Port Mid-Span Power Hub Power Cord Power Cord...
• Determine optimal placement. • Collect and document network information as required. • Ensure that the length of cable from the Ethernet network source to the powered device does not exceed 100 meters. Note: The units are not repeaters and do not amplify the Ethernet data signal. Caution: Observe the following requirements when mounting the Enterasys Networks Mid-Span Power Hubs: • The unit is intended for installation in a wiring closet. • Connect the unit to a grounding type AC outlet (100‐240 VAC), using the standard power cord shipped with the unit, or a user‐supplied UPS (uniterruptible power supply).
Powering Up Simply plug one end of the power cord into the unit, and the other end into a grounded AC power source. Units are typically connected to a power strip or other power outlet that may be cycled on and off. An uninterruptible power supply may also be used. Check to make sure each module installed displays a green Power LED (see Figure Verify that any module that does not display a green Power LED is properly seated in the chassis backplane. If problems exist, refer to the troubleshooting checklist in Chapter If you require assistance, contact Enterasys Networks using one of the methods described in “Getting Help” on page xii. 2-4 Installation and Connection Typical Configuration for a Mid-Span Power Hub Layer 3 Switch Enterasys BL-69108ENT or BL-69524ENT (shown) Mid-Span Power Hub Powered Devices IEEE802.3af Compatible 3, Troubleshooting. 2‐4). ...
Powering Up Figure 2-4 Module Bank for the 8-Port and 24-Port Mid-Span Power Hubs Power / Data Out (to device to be powered) Detect / Power Forwarding (Blue) Power (Green) Data In (from Ethernet switch) Mid-Span Power Hub User’s Guide 2-5...
Page 24
Powering Up 2-6 Installation and Connection...
Refer to Table 3‐1 for a checklist of problems and recommended actions to resolve the problem. If additional support is needed, refer to “Getting Help” on page xii. Table 3-1 Troubleshooting Checklist Problem Unit is plugged into the Enterasys Mid-Span Power Hub, but main power LED is “off.” Unit is plugged in and running, but the fans are not working. The Mid-Span Power Hub operates but one of the powered devices does not work.
Page 26
Table 3-1 Troubleshooting Checklist (continued) The Mid-Span Power Hub operates and the load device works, but there is no data link. The Mid-Span Power Hub operates, but one of the ports is powering a load without turning the “Power” LED on. 3-2 Troubleshooting Problem Verify that the Detect/Power Forwarding (blue)
Regulatory Compliance Standards This equipment meets the following safety and electromagnetic compatibility (EMC) requirements: Safety Electromagnetic Compatibility (EMC) Product Standards This equipment meets the following product standards: Standards Specifications Model BL-69108ENT • 8 female RJ45 data input ports • Shielded jacks for Category 5 or greater UTP (two pair wire) or 100‐ohm STP (two pair wire) • Distance: Up to 100 meters, standard Ethernet distance • 8 female RJ45 Data+Power on Ethernet (Power over Ethernet) output ports Hardware Specifications UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950, IEC 60950 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000-3-2, EN 61000-3-3, EN 55024, AS/NZS CISPR 22, VCCI V-3 IEEE 802.3af...
Specifications Model BL-69524ENT • 24 female RJ45 data input ports • Shielded jacks for Category 5 or greater UTP (two pair wire) or 100‐ohm STP (two pair wire) • Distance: Up to 100 meters, standard Ethernet distance • 24 female RJ45 Data+Power on Ethernet (Power over Ethernet) output ports Physical/Mechanical Specifications Table A‐1 provides physical and mechanical specifications for the 8‐port and 24‐port Mid‐Span Power Hubs. Table A-1 Physical and Mechanical Specifications Item BL-69108ENT Chassis Type Chassis Size Module Type Weight BL-69524ENT Chassis Type Chassis Size Module Type Weight LED Indicators/Module Table A‐2 provides module LED states and their definitions.
Physical/Environmental Specifications Table A‐2 provides physical and environmental specifications for the 8‐Port (BL‐69108ENT) and 24‐Port (BL‐69524ENT) Mid‐Span Power Hubs. Table A-3 Physical and Environmental Specifications Item Operating Temperature Storage Temperature Relative Humidity Operating Altitude Electrical Specifications AC Power Input Voltage Connector Chassis grounding Power supply DC Port Power Output Power enabling Power pins Maximum power/port Maximum power, all ports active Module-to-module isolation Overload protection...