Ricoh MP C2504 Field Service Manual page 829

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

6. Troubleshooting
SC No.
SC533-03
SC533-04
SC No.
SC534-01
SC534-02
SC534-03
820
Type
Error Name/Error Condition/Major Cause/Solution
D
PSU Cooling Fan Lock
D
Controller Box Cooling Fan Lock
In the motor ON state, the value of the lock sensor is checked every 0.1
sec.
If a lock signal is not obtained for 50 times consecutively.
• Motor defective
• Connector disconnected
• Harness broken
• IOB defective
• Replace the PSU exhaust fan for SC533-01, PSU cooling fan for
SC533-04 or controller box cooling fan for SC533-04.
• Reconnect the connector.
• Replace the harness.
• Replace the paper transport IOB (for SC533-01, -03).
• Replace the imaging IOB (for SC533-04).
Type
Error Name/Error Condition/Major Cause/Solution
D
Main Exhaust Fan Lock
D
Toner Supply Cooling Fan Lock
D
Ozone Exhaust Fan Lock

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c2004D243D244

Table of Contents