Ricoh MP C2504 Field Service Manual page 939

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

6. Troubleshooting
No.
SC841-00
No.
SC842-00
No.
SC842-01
No.
SC842-02
930
Type
Error Name/Error Condition/Major Cause/Solution
D
EEPROM read data error
Mirrored data of the EEPROM is different from the original data in
EEPROM.
Data in the EEPROM is overwritten for some reason.
-
Type
Error Name/Error Condition/Major Cause/Solution
C
Nand-Flash updating verification error
SCS write error (verify error) occurred at the Nand-Flash module when
remote ROM or main ROM was updated.
Nand-Flash defective
Turn the main power OFF/ON.
Type
Error Name/Error Condition/Major Cause/Solution
C
Insufficient Nand-Flash blocks (threshold exceeded)
At startup, or when machine returned from low power mode, the Nand-
Flash status was read and judged that the number of unusable blocks had
exceeded threshold, and then SCS generated the SC code.
Number of unusable blocks exceeded threshold for Nand-Flash
Replace the controller board.
Type
Error Name/Error Condition/Major Cause/Solution
C
Number of Nand-Flash block deletions exceeded
At startup, or when the machined returned from low power mode, the
Nand-Flash was read and judged that the number of deleted blocks had
exceeded threshold, and then SCS generated this SC code.
Number of blocks deleted exceeded threshold for Nand-Flash
Replace the controller board.

Advertisement