6. Troubleshooting
No.
[0x766d]
Console
string
No.
SC820-00
[0612]
920
Type
Error Name/Error Condition/Major Cause/Solution
VM full error
Occurs when too much RAM is used during system processing
"vm_pageout: VM is full"
Turn the main power OFF/ON.
Other error (characters on operation panel)
System detected internal mismatch error
• Software defective
• Insufficient memory
• Hardware driver defective (RAM, flash memory)
• Replace with a larger capacity RAM, or flash memory.
• Replace the controller board.
• Replace the connected controller option with a new one.
Type
Error Name/Error Condition/Major Cause/Solution
C
Self-diagnostics error: CPU
[XXXX]: Detailed error code
ASIC interrupt error
Interrupt occurs in an ASIC.
• ASIC device error
• Peripherals device error
• Replace the controller board
• Replace the connected controller option with a new one.

Advertisement