6. Troubleshooting
Waste toner bottle is never full
Target Part/SP No.: Waste Toner Bottle Full Sensor / SP5-803-032 (Toner Collection Full
Sensor)
Execute an INPUT check with feeler within the sensor detection range (Done
after removing the waste toner bottle)
Solution:
• Clean the sensor.
• Reconnect the connector.
• Replace the sensor.
• Replace the Imaging IOB.
• Replace the harness.
No waste toner bottle set is displayed on controller board even when it is clear that is
set
Target Part/SP No.:Waste Toner Bottle Set Sensor / SP5-803-033 (Toner Collection Bottle Set
Sensor)
Execute an INPUT check with the feeler within the sensor detection range
(Done after removing the waste toner bottle)
Solution:
• Reconnect the connector.
• Replace the sensor.
• Replace the Imaging IOB.
• Replace the harness.
1040
Cause verification
Cause verification
Problem Judgement
0: Not full
Problem Judgement
1: Not set