Ricoh MP C2504 Field Service Manual page 962

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

No.
Type
SC876-01
D
No.
Type
SC876-02
D
No.
Type
SC876-03
D
Error Name/Error Condition/Major Cause/Solution
Log Data Error 1
An error was detected in the handling of the log data at power on or
during machine operation.
Damaged log data file
Initialize the HDD (SP5-832-004).
Error Name/Error Condition/Major Cause/Solution
Log Data Error 2
An error was detected in the handling of the log data at power on or
during machine operation.
Log encryption is enabled but encryption module is not installed.
• Replace or set again the encryption module.
• Disable the log encryption setting.
Error Name/Error Condition/Major Cause/Solution
Log Data Error 3
An error was detected in the handling of the log data at power on or
during machine operation.
Inconsistency of encryption key between NV-RAM and HDD.
• Disable the log encryption setting.
• Initialize LCS memory (SP5801-019).
• Initialize the HDD (SP5-832-004).
Service Call 816-899
953

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c2004D243D244

Table of Contents