4. Replacement and Adjustment
Image Transfer Unit
Image Transfer Belt Unit
• Note that if the two levers [A] [B] are not pointing up, the image transfer belt unit cannot be
inserted.
• Before you remove or attach the image transfer belt unit, open the right door and the paper transfer
unit.
• Do not touch the rollers but hold the upper/lower resin parts [A] when you lift the Image Transfer
Unit. Touching the rollers may cause poor image quality.