Ricoh MP C2504 Field Service Manual page 1156

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

• SP3-102-011 to 014 (Toner Remain:Disp: Pixel Bk, C, M, Y)
Displays the remaining toner calculated from imaging size.
• SP3-102-021 to 024 (Toner Remaining: Display: Fill Amount Bk, C, M, Y)
Display the filler content of new bottle.
• SP3-120-001 to 004 (TE Sn Detect Thresh: Bk, C, M, Y)
Sets the starting threshold of the near-toner end detection by the toner end sensor.
• SP3-121-001 to 004 (TE Counter: Disp: Bk, C, M, Y)
Displays the number of times the toner end sensor detected toner end.
• SP3-122-001 to 004 (TE Sn NE Thresh: Bk, C, M, Y)
Sets the number of toner end detection to start near-toner end detection.
• SP3-163-001 (Bottle Drive: Set Rotation Time at Toner End)
Sets the empty turn time[ms] at almost toner-end.
• SP3-133-011 to 014 (TE Detect :Set Page Cnt:K, C, M, Y)
Displays the amount of sheets printed after toner near end is fixed.
• SP3-133-031 to 034 (TE Detect :Set Pxl Cnt:K, C, M, Y)
Displays the amount of toner used in cm2 after toner near-end is fixed.
• SP3-210-001 to 004 (TD.Sens:Vt :Disp: Current: K, C, M, Y)
Displays the latest TD sensor output.
• SP3-131-001 (Vt TE Thresh: Delta Vt Thresh)
Specifies the threshold to start adding the delta Vt after toner Near End.
• SP3-132-001 to 004 (Delta Vt Sum: Bk, C, M, Y)
Displays the integrated value of delta Vt.
• SP3-131-011 (Delta Vt Thresh BF NE)
Specifies the threshold to start integrating delta Vt before toner Near End.
• SP3-131-012 (Delta Vt Sum Thresh BF NE)
Specifies the threshold of delta Vt to check Toner End before toner Near End.
Toner Supply
1147

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c2004D243D244

Table of Contents