4. Replacement and Adjustment
3.
Apply the grease (FLUOTRIBO MG GREASE) to the rear shaft of the pressure roller at
5-7mm from the cut edge.
4.
Apply the grease (FLUOTRIBO MG GREASE) to the front shaft of the pressure roller at
5-7mm from the C-ring notch.

Fusing Sleeve Thermostat Unit

1.
Fusing upper cover
2.
Fusing lower cover