5. System Maintenance
Result Code
2 (INVALID REQUEST)
4 (INVALID OUTPUT
DIR)
7( MODULE ERROR)
8 (DISK FULL)
9 (DEVICE ERROR)
10 (LOG ERROR)
740
Cause
A file import was
attempted between
different models or
machines with different
device configurations.
Failed to write the device
information to the
destination device.
An unexpected error
occurred during import or
export.
The available storage
space on the external
medium is insufficient.
Failed to write or read the
log file.
The hard disk is faulty.
Solutions
Import files exported from the same model
with the same device configurations.
Check whether the destination device is
operating normally.
Switch the power off and then back on, and
then try the operation again. If the error
persists, contact your supervisor.
Execute the operation again after making
sure there is enough storage space.
Check whether the path to the folder for
storing the file or the folder in which the file is
stored is missing.
Contact your supervisor.