Category
45 and larger
ID Pattern detection
90 and larger
Result(End)
• Execution result example (In order of YMCK from left)
• Factory default (SP default): [00,00,00,00]
• Starting adjust: [99,99,99,99]
• Fail Vsg adjust(Y): [21,99,99,99]
• Error of Development gamma Max(C): [99,99,55,99]
• Succeeded: [11,11,11,11]
1122
Code
Result name
45
ID Pattern extract error
50
Vmin_Bk/K2 error (Max)
51
Vmin_Bk/K2 error (Min)
52
K5 error (Max)
53
K5 error (Min)
K5 calculated approximate
54
point error
Development gamma error
55
(Max)
Development gamma error
56
(Min)
Start developing voltage: Vk
57
error(Max)
Start developing voltage: Vk
58
error(Min)
59
Not enough valid data
90
Potential not adjusted
99
Stopped
Description
Cannot detect ID Pattern
K:Vmin_Bk / CMY:K2 > Max
K:Vmin_Bk / CMY:K2 < Min
K5 > Max
K5 < Min
K5 calculated approximate point <
Min
Development gamma > Max
Development gamma < Min
Start developing voltage: Vk > Max
Start developing voltage: Vk < Min
Adhesion amount data for
development gamma calculation
point is under 2.
Potential control method is set as
[0:FIX].
Stopped by door open, power off,
error. (Set when execute.)

Advertisement