6. Troubleshooting
Timing
After the
recovery from
energy saving
Printing
1074
Solutions
Set SP1-135-001 (Inrush
Control) to "1 (ON)".
Set SP1-135-002 (Flicker
Control) to "1 (ON)".
If it has not been improved in the
above, do the following
procedures in addition;
• Stop the lighting of the
fusing lamp after the warm-
up. Set SP1-121-001
(Switch:Rotation Start/
Stop:Time:After Reload) to
"0 sec".
Set SP1-135-002 (Flicker
Control) to "1 (ON)".
Side effect
• Recovery time from energy saving
becomes slower approx. 0.4 sec..
• In the case of the adhesion amount
of an image is large, an offset may
occur.
• In the case of a fusing offset
occurs, in the related SP to fusing
offsets, setting values must be
changed.
• The fusing temperature drops
during the operation. After
copying starts, the fusing
temperature is raised up to a
printable temperature. Because of
that, copying completion time
becomes slower (approx. 1-2
sec.).
• In the case of the adhesion amount
of an image is large, an offset may
occur.
• In the case of a fusing offset
occurs, in the related SP to fusing
offsets, setting values must be
changed.