SC No.
Type
SC665-07
D
Error Name/Error Condition/Major Cause/Solution
IPU signal Communication Error
The machine detects the communication error between CPU and Slave
device when starting up, or recovery from energy saver mode.
• FFC connection error
• FFC defective (disconnected, foreign object, etc.)
• The following board defects (Parts implementation defect, solder
scrap, implemented parts defect, etc.);
• BCU
• IPU
1. Turn the main power OFF/ON.
2. Reconnect the following FFC;
• BCU - Imagine IOB
• Imaging IOB - Paper Transport IOB
3. Replace the following FFC;
• BCU - Imagine IOB
• Imaging IOB - Paper Transport IOB
4. Replace the BCU.
5. Replace the IPU.
Service Call 620-687
863