4. Replacement and Adjustment
6.
TM/ID sensor [A]
Adjustment after Replacing the TM/ID sensor
1.
Turn on the main power switch, and then go into the SP mode.
2.
Run SP3-011-004 (Manual Procon: Exe Full MUSIC).
• If the SP3-011-004 can't finish successfully, make sure you are entering the correct value into
the SP.
Related SPs
• SP3-011-004 (Manual ProCon :Exe: Full MUSIC)
Executes Process Control and full MUSIC.
• SP3-012-001 to 010 (ProCon OK?: Front)
Displays the past 10 Process Control result codes detected by the front TM/ID sensor. The
code is 2 digits per color from the left, in the order of YMCK.
• SP3-012-011 to 020 (ProCon OK?: Center)
Displays the past 10 Process Control result codes detected by the center TM/ID sensor. The
code is 2 digits per color from the left, in the order of YMCK.
• SP3-012-021 to 030 (ProCon OK?: Rear)
Displays the past 10 Process Control result codes detected by the rear TM/ID sensor. The
code is 2 digits per color from left, in the order of YMCK.
ProCon results code
Category
00 and larger
502
Code
Result name
00
Not executed
Description
Factory default setting (SP default)