Ricoh MP C2504 Field Service Manual page 953

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

6. Troubleshooting
No.
* Do not format an SD card supplied with the main machine or sold as an option. You may only format SD
cards used for firmware update by a customer engineer.
No.
SC869-**
944
Type
Error Name/Error Condition/Major Cause/Solution
• SD card defective
• SD controller defective
Slot number is displayed on the sub code.
Detail code is described in SMC print can confirm the details of the error.
• -13 to -3: File system check error
• Otherwise (no code, -2) : Device access error
SD card that starts an application
1.
Turn the main power off and check the SD card insertion
status.
2.
If no problem is found, insert the SD card and turn the
main power on.
3.
If an error occurs, replace the SD card.
4.
If the error persists even after replacing the SD card,
replace the controller board.
SD card for users
1.
In case of a file system error, reformat the SD card (using
the "SD Formatter" made by Panasonic).*
In case of a device access error
1.
Turn the main power off and check the SD card insertion
status.
2.
If no problem is found, insert the SD card and turn the
main power on.
3.
If an error occurs, use another SD card.
4.
If the error persists even after replacing the SD card,
replace the controller board.
Type
Error Name/Error Condition/Major Cause/Solution
Malfunction of the proximity sensor (human detection sensor) is detected