Sets the new unit detection flag ON/OFF.
• SP3-701-116 [Manual New Unit Set: Fusing Belt]
Sets the new unit detection flag ON/OFF.
How to Clear SC544-02/SC554-02 with a New Unit Detection Fuse
1.
Install a new fusing sleeve belt unit.
2.
There is a new unit detection fuse packed with the new fusing sleeve belt unit.
3.
Connect the new unit detection fuse to the connector [A], and place the fuse in the empty
space [B].
4.
Reattach the fusing unit.
5.
Switch the power ON.
6.
Execute SP5-810-002 [SC Reset: Hard High Temp. Detection].
7.
Set SP3-701-116 [Manual New Unit Set: Fusing Belt] to "1".
(page
547)
Troubleshooting for SC Errors
975