Ricoh MP C2504 Field Service Manual page 938

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

No.
Type
SC838-00
C
[2701]
No.
Type
SC839-00
D
[9001]
No.
Type
SC840-00
D
Error Name/Error Condition/Major Cause/Solution
Self-diagnostic Error: Clock Generator
[xxxx]: Detailed error code
Verify error
A verify error occurred when setting data was read from the clock
generator via the I2C bus.
• Defective clock generator
• Defective I2C bus
• Defective I2C port on the CPU
Replace the controller board.
Error Name/Error Condition/Major Cause/Solution
Self-diagnostic Error: Serial Flash
[xxxx]: Detailed error code
Serial Flash access error
USB NAND Flash ROM cannot be read.
Defective controller board
Replace the controller board.
Error Name/Error Condition/Major Cause/Solution
EEPROM access error
• During the I/O processing, a reading error occurred. The 3rd
reading failure causes this SC code.
• During the I/O processing, a writing error occurred.
• Defective EEPROM
-
Service Call 816-899