If you are replacing a processor module after installing replacement DIMMs,
■
proceed to
10.
Finish the installation procedure.
See:
Install the processor module.
■
See
"Install a Processor Module or Processor Filler Module" on page
Return the server to operation.
■
See
"Returning the Server to Operation" on page
Verify DIMM functionality.
■
See
"Verify a DIMM" on page
Related Information
"Understanding DIMM Configurations" on page 69
■
"Understanding DIMM Configurations" on page 69
■
"Identifying DIMMs" on page 71
■
"Remove a DIMM" on page 78
■
"Verify a DIMM" on page 83
■
"DIMM Fault Handling" on page 74
■
"DIMM Configuration Errors" on page 72
■
Verify a DIMM
Access the Oracle ILOM prompt.
1.
Refer to the SPARC T7 Series Server Administration Guide for instructions.
2.
Use the show faulty command to determine how to clear the fault.
If show faulty indicates a POST-detected fault, go to
■
If show faulty output displays a UUID, which indicates a host-detected fault, skip
■
and go directly to
3.
Use the set command to enable the DIMM that was disabled by POST.
In most cases, replacement of a faulty DIMM is detected when the service processor is power
cycled. In those cases, the fault is automatically cleared from the server. If show faulty still
displays the fault, the set command will clear it.
Step
10.
83.
Step
4.
64.
201.
Step
3.
Servicing DIMMs
Verify a DIMM
Step 3
83
Need help?
Do you have a question about the SPARC T7-4 and is the answer not in the manual?
Questions and answers