Verify a Hard Drive
Ap_id Type
...
c2 scsi-sas connected configured unknown
c2::w5000cca00a76d1f5,0 disk-path connected
c3 scsi-sas connected configured unknown
c3::sd2 disk-path connected unconfigured unknown
c4 scsi-sas connected configured unknown
c4::w5000cca00a59b0a9,0 disk-path connected configured unknown
...
4.
Configure the drive using the cfgadm -c configure command.
For example:
# cfgadm -c configure c2::w5000cca00a76d1f5,0
Replace c2::w5000cca00a76d1f5,0 with the drive name for your configuration.
5.
Verify that the blue Ready-to-Remove LED is no longer lit on the drive that you
installed.
See
"Hard Drive LEDs" on page
6.
At the Oracle Solaris prompt, type the cfgadm -al command to list all drives in the
device tree, including any drives that are not configured.
# cfgadm -al
The replacement drive is now listed as configured. For example:
Ap_id Type
...
c2 scsi-sas connected configured unknown
c2::w5000cca00a76d1f5,0 disk-path connected
c3 scsi-sas connected configured unknown
c3::w5000cca00a772bd1,0 disk-path connected configured unknown
c4 scsi-sas connected configured unknown
c4::w5000cca00a59b0a9,0 disk-path connected configured unknown
...
7.
Perform one of the following tasks based on your verification results.
■
If the previous steps did not verify the drive, see
Process" on page
96
SPARC T7-4 Server Service Manual • May 2017
Receptacle
Occupant
configured unknown
89.
Receptacle
Occupant
configured unknown
26.
Condition
Condition
"Diagnostics
Need help?
Do you have a question about the SPARC T7-4 and is the answer not in the manual?
Questions and answers