Set 'ketswitch_state' to 'normal'
g.
Switch to the system console and check for faults.
# fmadm faulty
If any faults are reported, refer to the diagnostics instructions described in
Faults" on page
5.
Switch to the Oracle ILOM command shell.
6.
Run the show faulty command.
-> show faulty
Target
| Property
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0
| fru
/SP/faultmgmt/0
| timestamp
/SP/faultmgmt/0/
| sunw-msg-id
faults/0
|
/SP/faultmgmt/0/
| uuid
faults/0
|
/SP/faultmgmt/0/
| timestamp
faults/0
|
If the show faulty command reports a fault with a UUID, go on to
not report a fault with a UUID, you are done with the verification process.
7.
Switch to the system console and use the fmadm repair command with the UUID.
Use the same UUID that was displayed from the output of the Oracle ILOM show faulty
command. For example:
# fmadm repair 3aa7c854-9667-e176-efe5-e487e520
Related Information
"Understanding DIMM Configurations" on page 69
■
"Understanding DIMM Configurations" on page 69
■
"DIMM Fault Handling" on page 74
■
"DIMM Configuration Errors" on page 72
■
"Determine Which DIMM Is Faulty (DIMM Fault LEDs)" on page 76
■
"Determine Which DIMM Is Faulty (PSH)" on page 75
■
"Remove a DIMM" on page 78
■
"Install a DIMM" on page 80
■
33.
| Value
| /SYS/PM0/CM0/CMP/BOB10/D0
| Dec 14 22:43:59
| SUN4V-8000-DX
|
| 3aa7c854-9667-e176-efe5-e487e520
| 7a8a
| Dec 14 22:43:59
|
Verify a DIMM
"Check for
Step
7. If show faulty does
Servicing DIMMs
85