Replace the Battery
Press the new battery into the battery holder with the positive side (+) facing away from
the metal tab that holds it in place.
f.
Install the main module back into the server.
See
"Install the Main Module" on page
105.
Return the Server to
Operation.
g.
3.
Reset the system clock.
a.
Use the Oracle ILOM clock command to reset the system clock.
The following example sets the date to August 22, 2016, and the timezone to EDT.
-> set /SP/clock datetime=081221302016timezone=EDT
Set 'datetime' to '081221302016'
set 'timezone' to 'EDT'
-> show -d properties /SP/clock
Properties
datetime = Mon Aug 22 13:20:16 2016