Determine Which Dimm Is Faulty (Oracle Ilom); Determine Which Dimm Is Faulty (Psh) - Oracle SPARC T7-4 Service Manual

Hide thumbs Also See for SPARC T7-4:
Table of Contents

Advertisement

"Determine Which DIMM Is Faulty (DIMM Fault LEDs)" on page 76

Determine Which DIMM Is Faulty (Oracle ILOM)

If you suspect that the server has a memory problem, run the Oracle ILOM show
faulty command.
This command lists memory faults and identifies the DIMM modules associated with the fault.
Related Information
"Determine Which DIMM Is Faulty (PSH)" on page 75
"Determine Which DIMM Is Faulty (DIMM Fault LEDs)" on page 76

Determine Which DIMM Is Faulty (PSH)

The Oracle Fault Management tool fmadm faulty displays current server faults, including
DIMM failures.
Start the Fault Management Shell:
1.
-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y
2.
Type:
faultmgmtsp> fmadm faulty
------------------- ------------------------------------ -------------- ------
Time
UUID
------------------- ------------------------------------ -------------- ------
2014-08-18/21:04:40 7040d859-5b03-4a58-8dfd-e3a80875d62f SPSUN4V-8000-EJ Critical
Problem Status
: solved
Diag Engine
: fdd 1.0
System
Manufacturer
: Oracle Corporation
Name
: SPARC T7-4
Part_Number
: 7021179
Serial_Number : 1201CTHC01
System Component
Manufacturer
: Oracle Corporation
Name
: SPARC T7-4
Part_Number
: 7021179
Determine Which DIMM Is Faulty (Oracle ILOM)
msgid
Severity
Servicing DIMMs
75