Determine Which Hard Drive Is Faulty

Determine Which Hard Drive Is Faulty
The following LEDs are lit when a hard drive fault is detected:
System Service Required LEDs on the front panel and rear I/O module
Service Required LED on the faulty drive
1.
Determine if the System Service Required LEDs are lit on the front panel or the
rear I/O module.
See
"Interpreting LEDs" on page
2.
From the front of the server, check the drive LEDs to identify which drive needs
to be replaced.
See
"Hard Drive LEDs" on page
that needs to be replaced.
3.
Remove the faulty drive.
See
"Remove a Hard Drive" on page
Related Information
"Hard Drive Configuration" on page 87
"Hard Drive Configuration" on page 87
"Hard Drive LEDs" on page 89
"Remove a Hard Drive" on page 90
"Install a Hard Drive" on page 94
"Verify a Hard Drive" on page 95

Remove a Hard Drive

Hard drives are hot-service components that can be replaced by customers. For the location of
the hard drives, see
Caution -
discharge. This discharge can cause failure of server components.
1.
Locate the drive in the server that you want to remove.
See
90
SPARC T7-4 Server Service Manual • May 2017
"Hard Drive Configuration" on page
This procedure requires that you handle components that are sensitive to electrostatic
"Hard Drive Configuration" on page 87
27.
89. The amber Service Required LED is lit on the drive
90.
87.
for the locations of the drives in the server.