See
"Power On the Server (Oracle ILOM)" on page
2.
Check the front or rear panel LEDs for the following:
Green System OK LED – lit
■
Amber System Fault LED – not lit
■
Amber System Fan Fault LED – not lit
■
See
"Front Panel Controls and LEDs" on page 29
LEDs" on page
31.
If these conditions are met, continue to
If these conditions are not met, perform the actions described in
Process" on page
26.
Log in to Oracle ILOM.
3.
See
"Log In to Oracle ILOM (Service)" on page
4.
Start the faultmgmt shell.
-> start SP/faultmgmt/shell
Are you sure you want to start the faultmgmt shell (y/n)? y
faultmgmtsp>
5.
Use the fmadm faulty command to check for faults.
If faults are reported, see
■
If no faults are reported, then the fan module has been replaced successfully.
■
Related Information
"Determine Which Fan Module Is Faulty" on page 158
■
"Remove a Fan Module" on page 159
■
"Install a Fan Module" on page 161
■