No.
LED
Related Information
"Determine if the Main Module Is Faulty" on page 101
■
"Remove the Main Module" on page 101
■
"Install the Main Module" on page 105
■
Determine if the Main Module Is Faulty
Check the Service Required LED on the main module.
The Service Required LED is lit when the server detects a main module fault.
Related Information
"Main Module LEDs" on page 100
■
"Remove the Main Module" on page 101
■
"Install the Main Module" on page 105
■
Remove the Main Module
(Optional) If you are replacing a faulty main module, you must back up ILOM
1.
configuration settings.
Configure the SER MGT port to enable the configuration parameters to be
a.
uploaded.
Refer to the ILOM documentation for network configuration instructions.
b.
Back up the ILOM configuration parameters.
Refer to the
2.
Ensure that the server is powered off. Power off the server.
Icon
Description
■ Steady on, green – SPM is running in its normal operating state. No
service actions are required.
■ Blink, green – SPM is initializing the Oracle ILOM firmware.
■ Steady on, amber – A SPM error has occurred and service is
required.
ILOM documentation
(http://www.oracle.com/goto/ILOM/docs).
Determine if the Main Module Is Faulty
Servicing the Main Module
101
Need help?
Do you have a question about the SPARC T7-4 and is the answer not in the manual?
Questions and answers