74
C
2: I
HAPTER
NSTALLING AN
Sample Services Configuration Script — Primary Server (continued)
Polling Frequency (seconds)
A 'low battery' condition is reached when the battery charge reaches a
defined threshold percentage.
Low Battery Threshold (%)
Do you wish to change any of the UPS Monitoring parameters? [N] :
-------- Configuring additional parameters for IP Messaging Service --------
The hostname of the other IP Messaging system is needed in order to set up
Intelligent Mirroring redundancy with this system.
Hostname of peer IP Messaging system
When multiple IP Messaging systems are in use, for example at a region and
one or more branches, the Global Voicemail capability allows these systems
to act as a single unified voicemail system.
participates in Global Voicemail.
Is Global Voicemail enabled? [N]
IP Messaging includes an optional ability to archive messages to an
external server.
IP T
M
ELEPHONY AND
ESSAGING
If this server is a UPS Master, it polls the UPS at the interval that you
specify here. Press the Enter or Return key to accept the default answer
(30 seconds) or enter the frequency desired, in seconds.
Press the Enter or Return key to accept the default answer (25%) or enter
a different threshold percentage. When the UPS battery reaches this
threshold, the VCX server will log the event through syslog, generate an
SNMP trap indicating that shutdown is imminent, and start an orderly
shutdown of services and the VCX operating system.
Press the Enter or Return key to accept the default answer (N). If you
want to change any of the values, enter Y.
Enter the IP address of the other IP Messaging system.
Press the Enter or Return key to accept the default answer (Y) if you want
to use Global Voicemail.
S
ERVER
:
:
:
Say 'yes' here if this system
:
Need help?
Do you have a question about the VCX V7000 and is the answer not in the manual?
Questions and answers