444
A
C: R
PPENDIX
EPLACING A
Replacing an IP
Messaging Disk
F
D
VCX S
AILED
ISK ON A
A VCX system that is configured for global IP Messaging has one IP
Messaging Server in each regional office. The secondary IP Messaging
server is located in the remote regional office.
A VCX system that is configured for local IP Messaging has a Primary and
Secondary IP Messaging Server in each regional office.
Use the instructions in this section to replace the disk on a Primary or
Secondary IP Messaging Server in a global or local IP Messaging
configuration.
If this server is configured for RAID operation, see
earlier in this appendix.
1 Replace the failed disk.
a Remove power from the down server.
b Remove the failed disk.
c Install the replacement disk.
d Apply power to the server.
e Press the start button on the front panel.
2 Log in as root and configure the networking parameters on the down
server using this command:
vcx-config-network --wizard
If the down server is the primary IP Messaging Server, follow the
instructions in
"Configuring a Primary IP Messaging Server"
If the down server is the Secondary IP Messaging Server, follow the
instructions in
"Configuring a Secondary IP Messaging Server"
Chapter
4.
3 If necessary, upgrade the software version on the down server to match
the software version on the running server.
a Compare the software version on the down server to the software
version on the running server.
On the running server and on the down server, enter this command:
vcx-showversion
b If the down server is running an earlier software version than the
running server, download the appropriate software upgrade file to the
/opt/installtemp
ERVER
directory on the down server.
"RAID Disk
Failure",
in
Chapter
in
4.

Advertisement

Table of Contents