Sample Services Configuration Script — Primary IP Telephony Server (continued)
Enter the IP address assigned to the second UPS's management card or
Ethernet interface.
address.
Second UPS IP address
The SNMP 'write' community string configured in the second UPS is required.
Second UPS 'write' community string
The VCX system polls the UPS at regular intervals to get status
information.
A shorter interval makes the system more responsive to UPS
status changes, but consumes more network bandwidth. The default value
should work for most systems.
Polling Frequency (seconds)
A 'low battery' condition is reached when the battery charge reaches a
defined threshold percentage.
Low Battery Threshold (%)
Do you wish to change any of the UPS Monitoring parameters? [N] :
Note: The UPS must already be configured with this
If you are using a second UPS, enter the IP address of the second UPS's
management card or Ethernet interface. If you are not using a second
UPS, press the Enter or Return key to leave this field blank.
If this server is a UPS Master, it polls the UPS at the interval that you
specify here. Press the Enter or Return key to accept the default answer
(30 seconds) or enter the frequency desired, in seconds.
Press the Enter or Return key to accept the default answer (25%) or enter
a different threshold percentage. When the UPS battery reaches this
threshold, the VCX server will log the event through syslog, generate an
SNMP trap indicating that shutdown is imminent, and start an orderly
shutdown of services and the VCX operating system.
Press the Enter or Return key to accept the default answer (N). If you
want to change any of the values, enter Y.
:
: private
:
: