354
A
B: A
PPENDIX
UTOMATED
Sample V6000 Media Gateway Configuration File (continued)
V22ModemTransportType = 0
V23ModemTransportType = 0
V32ModemTransportType = 0
V34ModemTransportType = 0
FaxRelayRedundancyDepth = 2
FaxModemBypassCoderType = 1
BasicRTPPacketInterval = 3
CNGDetectorMode = 2
B
O
I
RANCH
FFICE
NSTALLATION
Specify the transport type for these modems. Possible values are:
0 — Transparent
■
1 — Relay
■
2 — Bypass
■
NOTE: V32ModemTransportType applies to V.32 and V.32bis modems.
NOTE: V34 ModemTransportType applies to V.34 and V.90 modems.
Specify the number of times that each fax relay payload is retransmitted
to the network. Possible values are 0 (default), 1, and 2.
Specify the type of coder to be used when performing fax modem
bypass. Possible values are:
0 — G711 A-law 64 (default)
■
μ
1 — G711
-law
■
4 — G726 32
■
11 — G726 40
■
Set this parameter using the web browser interface. Navigate to Protocol
Definition > Coders and set the value there. The value that you select
appears in the INI file when the file is exported.
Set this value to determine whether you want fax sessions to start when
the fax calling tones are detected. Possible values are:
0 — Don't detect fax calling tones (default)
■
1 — Not applicable
■
2 — Detect fax calling tones and start the fax session.
■