Siemens SINUMERIK 840Di sl Operating Manual page 283

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

6
01/2008
Automatic determination
through synchronization
© Siemens AG 2008 All rights reserved.
SINUMERIK 840Di sl/840D sl/840D Operating Manual HMI-Advanced (BAD) - 01/2008 Edition
Additional keys that are not listed in the dialog box, but decisive for
setting the ASCII full view:
In SEDITOR.INI also in section [MultiASCIIView]
"ZoomFont" key
Specifies whether the font of the editors should be zoomed in the
m-ASCII view - or not.
0 – VGA font, the font is not zoomed (default)
1 – the font is zoomed
In MCSE.INI in section [General]
"SwitchHSK7_15" key
This specifies whether in MCSP the HSK7 is assigned with
"Simulation" or with "Editor large|small" in exchange with HSK15.
0 – no exchange (default)
1 – exchange HSK7 with HSK15 contents
For the automatic channel selection, starting from the step currently in
focus in the step view, the next synchronization step is determined. Of
course, initially it is checked as to whether the step current in focus is
a synchronization step. If it is not a synchronization step, then
depending on the selected search direction, a search is either made
upwards or downwards.
If a synchronization step was able to be found, then from this
associated synchronizing channels/MPFs are determined.
Example:
A WAITM(99,2,3,5,7) in channel 3 supply the synchronizing channels
2, 5 and 7. To start, the found synchronizing channels/MPFs are
filtered as to whether the files are also currently opened in the MCSE.
Channels/MPFs that are not in the synchronization command are
ignored. For instance, referred to WAITM(99,2,3,5,7): Existing
channels: 2, 3, 5
synchronizing channel 7 is ignored.
A check is then made as to whether the number of channels to be
displayed was complied with.
The following rules apply:
The number of channels to be displayed (refer to the entry
"number of channels") must lie between 1 and 4.
If a larger number is obtained from the number of filtered
synchronizing channels, then starting from the channel currently
in focus, a search is made to the left (sequence of the channels
as in the graphic step view) for channels to be displayed - and if
required, the search is continued from the far right to the left:
REMOVE
If a smaller number is obtained from the number of filtered
synchronizing channels, then starting from the channel currently
in focus (sequence of the channels as in the graphic step view), a
search is made for channels that are still not to be displayed -
and if required, the search is continued from the far left to the
right:
Fill-up
"Program" operating area
6.6
Multiple editor (option)
6
6-283

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d slSinumerik 840d