Siemens SINUMERIK 840Di sl Operating Manual page 126

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

4
Machine operating area
4.4
JOG mode
4-126
Protection levels are available for the following system frames:
System
MD
frame
number
ToolFrame
9183
PartFrame
9184
WPFrame
9185
CYCFrame
9186
TraFrame
9187
ExtFrame
9188
SetFrame
9210
Note:
In the case of SetFrame, the same machine data applies as for
settable work offsets, as this practically does constitute a work offset.
This also applies to SetFrame fine offset, in respect of which no user
intervention is permitted. For fine offset of the settable work offsets,
there is a dedicated machine data:
9203 $MM_USER_CLASS_WRITE_FINE. The associated protection
level is generally lower than for coarse offset.
Further information:
Set zero point corresponds to $P_SETFR
Ext. WO frame
Toolholder
corresponds to $P_PARTFR
Tool reference corresponds to $P_TOOLFR
Workpiece ref. corresponds to $P_WPFR
Cycles
See also Subsection 4.4.6
SINUMERIK 840Di sl/840D sl/840D Operating Manual HMI-Advanced (BAD) - 01/2008 Edition
Name/description
$MM_USER_CLASS_WRITE_TOOLFRAME
Protection level write toolholder
$MM_USER_CLASS_WRITE_PARTFRAME
Protection level write tool reference point
$MM_USER_CLASS_WRITE_WPFRAME
Protection level write workpiece reference
point
$MM_USER_CLASS_WRITE_CYCFRAME
Protection level write cycle frame
$MM_USER_CLASS_WRITE_TRAFRAME
Protection level write transformation frame
$MM_USER_CLASS_WRITE_EXTFRAME
Protection level write external WO
$MM_USER_CLASS_WRITE_ZOA
Protection level write settable WO
corresponds to $P_EXTFR
corresponds to $P_CYCFR
© Siemens AG 2008 All rights reserved.