Interface; Parameterizing The V.24 Interface - Siemens SINUMERIK 840Di sl Operating Manual

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

7
Services operating area
7.5
V.24 interface
7.5
V.24 interface

7.5.1 Parameterizing the V.24 interface

Parameters for
DIN programs
Parameters for archiving
with PG/PC
7-382
Function
Default: V.24 user
Interface: COM1
Protocol: RTS/CTS
Parity: None
Stop bits: 1
With header and trailer labels
Data bits: 8
Stop with end of data transfer character
Baud rate: 9600
Archive format: Punched tape with ... time monitoring (sec.): 04
With this setting, programs according to DIN are downloaded (starting
with %) or output.
Default: V.24 PG/PC
Interface: COM2
Protocol: RTS/CTS
Parity:
Stop bits: 1
Data bits: 8
Baud rate: ≥ 9600
Archive format: Binary format (PC format)