882 Video Test Instrument User Guide (Rev A.35)
Self-calibrating–Analog video outputs are automatically adjusted against an internal
precision reference. This assures video levels that are precise and reliable. Signal
levels are auto-adjusted individually.
Probe–Trigger a scope or inspection camera using the probe signal. Position a pulse
anywhere in the frame.
PC Card–Clone one 882 to another using a standard CompactFlash card.
Auxiliary Channel Analyzer (ACA) –The ACA enables you to monitor DDC, HDCP, CEC
and EDID transactions for HDMI and HDCP, Link Layer and EDID transactions over the
DisplayPort auxiliary channels.
IEEE-488-GPIB (IEEE-488) interface. interface.
RS-232-Industry standard serial interface.
882E Optional Features
The following are the optional features available with the 882E. For the 882E one of the
two following options must be selected:
HDMI 1.3 Transmitter:
Advanced E-EDID parsing
Deep Color at 24/30/36-bit/pixel 4:4:4 RGB / YCbCr
16/20/24-bit/pixel 4:2:2 YCbCr
High-level Active Format Description (AFD) controls
AFD test suite
Pixel repetition test suite
Automatic and manual InfoFrame setup
Compressed Dolby Digital formats (Plus & TrueHD)
Internal sine wave 882 (LPCM), and external SPDIF audio input
32, 44.1, 48, 88.2, 176.4 and 192kHz audio sampling rates
Generates all EIA/CEA-861D formats below 165 MHz, with all possible variations
Complete letterbox and scope coverage
4:2:2 color sub-sampling at 8, 10, and 12-bits per component
Hot-plug format list
Includes DVI-D (M) to HDMI (M) cable and HDMI-HDMI cable.
Analog Video component and composite (881E/882E only)
Component analog up to 250MHz
Component analog VGA Connector