DVC6200f Digital Valve Controller
PID Function Block
February 2017
Table E‐6. PID Function Block System Parameters Definitions
Label
PARAMETER_NAME
Update Event
UPDATE_EVT
UNACKNOWLEDGED
UPDATE_STATE
TIME_STAMP
STATIC_REVISION
RELATIVE_INDEX
Block Alarm
BLOCK_ALM
UNACKNOWLEDGED
ALARM_STATE
TIME_STAMP
SUBCODE
VALUE
Alarm Summary
ALARM_SUM
CURRENT
UNACKNOWLEDGED
UNREPORTED
DISABLED
Acknowledge Option
ACK_OPTION
Alarm Hysteresis
ALARM_HYS
High High Priority
HI_HI_PRI
High High Limit
HI_HI_LIM
High Priority
HI_PRI
High Limit
HI_LIM
Low Priority
LO_PRI
Low Limit
LO_LIM
Low Low Priority
LO_LO_PRI
234
Index
RO /
Block
Number
RW
Mode
43
0=Undefined
43.1
RW
N/A
1=Acknowledged
2=
0=Undefined
43.2
RO
N/A
1=Update reported
2=Update not reported
43.3
RO
N/A
43.4
RO
N/A
43.5
RO
N/A
44
0=Undefined
44.1
RW
N/A
1=Acknowledged
2=
0=Undefined
1=Clear‐reported
44.2
RO
N/A
2=Clear‐not reported
3=Active reported
4=Active not reported
44.3
RO
N/A
44.4
RO
N/A
44.5
RO
N/A
45
1: High High Alarm
45.1
RO
ALL
2: High Alarm
45.2
RO
ALL
3: Low Low Alarm
4: Low Alarm
45.3
RO
ALL
5: Deviation High Alarm
6: Deviation Low Alarm
45.4
RW
ALL
7: Block Alarm
1: High High Alarm
2: High Alarm
3: Low Low Alarm
46
N/A
4: Low Alarm
5: Deviation High Alarm
6: Deviation Low Alarm
7: Block Alarm
47
ALL
0 to 50%
48
ALL
0 to 15
49
ALL
PV_SCALE, or +INF
50
ALL
0 to 15
51
ALL
PV_SCALE, or +INF
52
ALL
0 to 15
53
ALL
PV_SCALE, or -INF
54
ALL
0 to 15
Range
Initial Value
Unacknowledged
Unacknowledged
Dynamic
All bits: 0
0.50%
+INF
+INF
-INF
Instruction Manual
Description
0
Data Type: DS‐73
This alert is generated by any changes to the static
0
data.
0
0
0
0
Data Type: DS‐72
The block alarm is used for all configuration,
hardware, connection failure, or system problems
in the block. The cause of the alarm will be set in
0
the subcode.
VALUE Data Type: Unsigned8
0
0
0
Data Type: DS‐74
Current alert status, unacknowledged states,
unreported states, and disabled states of the
alarms associated with the function block.
Data Type: Bit String
0=Disable
1=Enable
Used to set auto acknowledgment of alarms.
Data Type: Float
The amount the alarm value must return to within
the alarm limit before the associated active alarm
condition clears.
Data Type: Unsigned8
0
The priority of the HI HI Alarm.
Data Type: Float
The setting for the alarm limit used to detect the
HI HI alarm condition.
Data Type: Unsigned8
0
The priority of the HI alarm.
Data Type: Float
The setting for the alarm limit used to detect the
HI alarm condition.
Data Type: Unsigned8
0
The priority of the LO alarm.
Data Type: Float
The setting for the alarm limit used to detect the
LO alarm condition.
Data Type: Unsigned8
0
The priority of the LO LO alarm.
D103412X012