Fisher FIELDVUEDVC6200f Instruction Manual page 329

Digital valve controller for foundation fieldbus
Table of Contents

Advertisement

Instruction Manual
D103412X012
Note
Before beginning the Add Device Definition procedure, it is recommended that the Add Device Utility be installed on DeltaV. This
may help prevent installation errors from occurring.
Table F‐1. Methods
Method
Auto Calibration
Block Error Reporting
Block Mode
Display DD Version
Instrument Alerts
Manual Travel Calibration
Output A Sensor Calibration
Output B Sensor Calibration
Field Diagnostic Alerts
Relay Adjust
Reset Options
Device Setup
Stabilize/Optimize
Stroke Valve
Supply Sensor Calibration
Define Custom Characteristic
Travel Deviation Fallback
Outblock Selection
Field Diagnostic Alerts Set PV Status
Performance Tuner
Note
Be sure to select the correct DD for the DeltaV revision being used. The resource files are different for each revision of DeltaV.
D Device descriptions furnished by Fisher contain only those files applicable to Fisher. All the files are located in the
manufacturer ID Folder (005100 for xxxxxx in directory structure above). A readme file is included at the top level.
Read this file for any additional information regarding DD installation.
D Device descriptions furnished by the Fieldbus Foundation (on CD‐ROM or diskette) contain the files for each
registered manufacturer and their associated device(s). It is placed on the media starting with the release folder,
which then contains a folder (xxxxxx) for each manufacturer as defined above. For Fisher this folder is 005100. A
readme file may be included at the top level. Read this file for any additional information regarding the DD.
D For the DVC6200f—The device type parameter for this unit is 4602. This device includes the AO, PID, CSEL, ISEL, OS,
AI, MAI, DO and DI function blocks. From DeltaV Explorer, select the amsdevices\005100\4602 folder (refer to
figure F‐2).
Block
Description Location
Transducer
page 120
Transducer
page 67
Transducer
page 47
Resource
page 23
Resource
page 331
Transducer
page 54
Transducer
page 120
Transducer
page 123
Transducer
page 123
Transducer
page 54
Transducer
page 121
Resource
page 128
Transducer
page 18
Transducer
page 50
Transducer
page 133
Transducer
page 122
Transducer
page 53
Transducer
page 52
Transducer
page 54
Transducer
page 67
Transducer
page 22, 49
DVC6200f Digital Valve Controller
Device Description Installation
February 2017
329

Advertisement

Table of Contents
loading

Table of Contents