Fisher FIELDVUEDVC6200f Instruction Manual page 170

Digital valve controller for foundation fieldbus
Table of Contents

Advertisement

DVC6200f Digital Valve Controller
Field Communicator Menu Structure
February 2017
Transducer Block (TB) Menu Structure
Parameter Label
Reset Stroke Time Alert
Reset Stroke Time Alert Enable
Reset Stroke Time Alert Point
Reset Travel History
Seat Type
Set Point Overdrive
Shaft Stem Diameter
Simulate Jumper ON
Spring Rate
Spring Rate Units
Stabilize/Optimize
Static Memory Alert
Static Memory Alert Enable
Static Memory Manual Recovery
Static Memory Shutdown
Stroke History FD-PD FD Config
Stroke History PST FD Config
Stroke Test Overdue FD Config
Stroke Valve
Stroking Time Close
Stroking Time Open
Supply
Supply Pressure Calibration
Supply Pressure FD Config
Supply Pressure High Alert
Supply Pressure High Alert
Enable
Supply Pressure High Alert Point
Supply Pressure Low Alert
Supply Pressure Low Alert Enable
Supply Pressure Low Alert Point
Supply Pressure Sensor Alert
Supply Pressure Sensor Alert
Enable
Supply Pressure Sensor FD
Config
Supply Sensor Failure
Tag Description
TB Block Modes
Temperature
Temperature High Alert
Temperature High Alert Enable
Temperature High Alert Point
Temperature Limit FD Config
Temperature Low Alert
Temperature Low Alert Enable
Temperature Low Alert Point
Temperature Sensor Alert
Temperature Sensor Alert Enable
Temperature Sensor FD Config
Temperature Units
Test Abnormal Cause
170
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Device Variables
Travel Diagnostic Info
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Device Diagnostics
PST/FST
>
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Device Diagnostics
Status
Self Test Status
>
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Device Diagnostics
Stroke Valve
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Device Variables
Pressures
>
>
>
TB
Configure/Setup
Calibration
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Device Diagnostics
Status
Self Test Status
>
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Device Variables
TB Block Modes
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Device Variables
Instrument Info
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Configure/Setup
Detailed Setup
>
>
TB
Device Diagnostics
PST/FST
>
>
>
Menu Structure
Alerts
Travel History Alerts
>
>
>
Alerts
Travel History Alerts
>
>
>
Alerts
Travel History Alerts
>
>
>
Reset Travel History
>
Valve and Actuator
Trim
Seat Type
>
>
>
PST/FST Info
Set Point Overdrive
>
Valve and Actuator
Valve
Shaft Stem Diameter
>
>
>
Simulate Jumper ON
>
Valve and Actuator
Actuator
>
>
Instrument
Units
Spring Rate Units
>
>
>
Response Control
Travel Tuning
>
>
Alerts
Electronic Alerts
Processor Impaired
>
>
>
Alerts
Electronic Alerts
Processor Impaired
>
>
>
Alerts
Electronic Alerts
Processor Impaired
>
>
>
Alerts
Electronic Alerts
Processor Impaired
>
>
>
Alerts
Travel History Alerts
>
>
>
Alerts
Travel History Alerts
>
>
>
Alerts
FST/PST Alerts
Stroke Test Overdue
>
>
>
Valve and Actuator
Actuator
>
>
Valve and Actuator
Actuator
>
>
Alerts
Environment Alerts
>
>
>
Supply
Supply Pressure
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Sensor Alerts
Pressure Sensors
>
>
>
Alerts
Sensor Alerts
Pressure Sensors
>
>
>
Alerts
Sensor Alerts
Pressure Sensors
>
>
>
Supply Sensor Failure
>
Instrument
Tag Description
>
>
Alerts
Environment Alerts
>
>
>
Temperature
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Environment Alerts
>
>
>
Alerts
Sensor Alerts
Temperature Sensor
>
>
>
Alerts
Sensor Alerts
Temperature Sensor
>
>
>
Alerts
Sensor Alerts
Temperature Sensor
>
>
>
Instrument
Units
Temperature Units
>
>
>
PST/FST Info
Test Abnormal Cause
>
Instruction Manual
Stroke History PST
Reset Stroke Time Alert
>
Stroke History PST
Reset Stroke Time Alert Enable
>
Stroke History PST
Reset Stroke Time Alert Point
>
Spring Rate
>
Stabilize/Optimize
>
Static Memory Alert
>
Static Memory Alert Enable
>
Static Memory Manual Recovery
>
Static Memory Shutdown
>
Stroke History FD-PD
Stroke History FD-PD FD Config
>
Stroke History PST
Stroke History PST FD Config
>
Stroke Test Overdue FD Config
>
Stroking Time Close
>
Stroking Time Open
>
Supply Pressure
Supply
>
Supply Pressure
Supply Pressure FD Config
>
Supply Pressure
Supply Pressure High Alert
>
Supply Pressure
Supply Pressure High Alert Enable
>
Supply Pressure
Supply Pressure High Alert Point
>
Supply Pressure
Supply Pressure Low Alert
>
Supply Pressure
Supply Pressure Low Alert Enable
>
Supply Pressure
Supply Pressure Low Alert Point
>
Supply Pressure Sensor Alert
>
Supply Pressure Sensor Alert Enable
>
Supply Pressure Sensor FD Config
>
Temperature Limit
Temperature
>
Temperature Limit
Temperature High Alert
>
Temperature Limit
Temperature High Alert Enable
>
Temperature Limit
Temperature High Alert Point
>
Temperature Limit
Temperature Limit FD Config
>
Temperature Limit
Temperature Low Alert
>
Temperature Limit
Temperature Low Alert Enable
>
Temperature Limit
Temperature Low Alert Point
>
Temperature Sensor Alert
>
Temperature Sensor Alert Enable
>
Temperature Sensor FD Config
>
D103412X012

Advertisement

Table of Contents
loading

Table of Contents