Extended Setpoint Channel
Extended setpoint channel
2.2
Extended setpoint channel
2.2.1
Description
In the extended setpoint channel, setpoints from the setpoint source are condi-
tioned for motor control.
The setpoint for motor control can also originate from the technology controller
(see Technology Controller).
Motorized
potentiometer
Setpoint channel
Motor control
Fig. 2-1
Extended setpoint channel
Properties of the extended setpoint channel
S Main/supplementary setpoint, setpoint scaling
S Direction of rotation limiting and direction of rotation changeover
S Suppression bandwidths and setpoint limitation
2-44
Setpoint sources
Analog
Speed
inputs
fixed setpoints
Supplementary
Main setpoint
Main/supplementary setpoint
Setpoint scaling
Direction of rotation limiting
Direction of rotation reversal
Suppression bandwidths
Setpoint limitation
Ramp-function generator
Motor control
Servo/vector
© Siemens AG 2006 All Rights Reserved
SINAMICS S120 Function Manual, 03/2006 Edition
Field bus
Jog
setpoint