Smart Infeed Open-Loop Control - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Key parameters for line and DC link identification (see List Manual)
S p3410
S p3421
S p3422
1.2.3

Smart Infeed open-loop control

Description
The Smart Line Module can be controlled via the BICO interconnection by means
of terminals or the field bus. The operating status is indicated on the operating dis-
play r0002. The missing enable signals for operation (r0002 = 00) are mapped in
parameter r0046. The EP terminals (enable pulses) must be connected in accor-
dance with the Equipment Manual.
Acknowledge error
Errors that are still present but the causes of which have been rectified can be ac-
knowledged by means of a 0 –> 1 edge at the "Acknowledge error" (p2103.5) signal.
© Siemens AG 2006 All Rights Reserved
SINAMICS S120 Function Manual, 03/2006 Edition
Infeed identification method
Infeed inductance
Infeed DC link capacity
Infeed
Smart Infeed
1-31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents