Extended Functions
"Extended brake control" function module
4.4.5

Commissioning

The extended brake control function can be activated while the commissioning
Wizard is running. Parameter r0108.14 indicates whether the function module has
been activated.
Unless you change the default settings, the extended brake control function beha-
ves in exactly the same way as the simple brake control function.
The brake control is activated automatically (p1215 = 1) if the Motor Module has an
internal brake control function and a connected brake has been found.
If the component does not have an internal brake control function, control can be
activated via parameter (p1215 = 3).
Caution
If p1215 = 0 (no brake available) is set when a brake is present, the drive runs with
applied brake. The can destroy the brake.