Operating Modes
Information on commissioning vector motor types
The following parameters can be entered in STARTER during the commissioning
phase:
Table 3-22
Parameter
p0304
p0305
p0311
p0314
p0316
If the torque constant k
data sheet, then you can calculate this value from the rated motor data or from the
stall current I
M
+
+
N
k
T
I
N
M
+
o
k
T
I
o
Table 3-23
Parameter
p0320
p0322
p0323
p0328
p0341
p0342
p0344
p0350
p0356
p0357
3-174
Motor data
Description
Rated motor voltage
Rated motor current
Rated motor speed
Motor pole pair number
Motor torque constant
is not stamped on the rating plate or specified in the
T
and stall torque M
as follows:
o
o
s
60
* P
N
min
or
2p * n
* I
N
N
Optional data
Description
Motor rated magnetization
current/short-circuit current
Maximum motor speed
Maximum motor current
PE spindle, reluctance torque
constant
Motor moment of inertia
Ratio between the total and
motor moment of inertia
Motor weight
Motor stator resistance, cold
Motor stator inductance Lq
Motor stator inductance Ld
Comments
If this value is not known, then a
"0" can also be entered. Using
this value, the stator leakage
inductance can be more
precisely calculated (p0356,
p0357).
Comments
This is used for the field
weakening characteristic
Maximum mechanical speed
De-magnetization protection
For speed controller pre-control
For a thermal motor model – not
relevant for synchronous motors