Induction motors, rotating
The following parameters can be entered in STARTER during the commissioning
phase:
Table 3-20
Parameter
p0304
p0305
p0307
p0308
p0310
p0311
p0335
The following parameters can be optionally entered:
Table 3-21
Parameter
p0320
p0322
p0341
p0342
p0344
p0350
p0352
p0354
p0356
p0358
p0360
p0640
p1080
© Siemens AG 2006 All Rights Reserved
SINAMICS S120 Function Manual, 03/2006 Edition
Information on commissioning vector motor types
Motor data, rating plate
Description
Rated motor voltage
Rated motor current
Rated motor power
Rated motor power factor
Rated motor frequency
Motor rated speed
Motor cooling type
Optional motor data
Description
Motor rated magnetization
current/short-circuit current
Maximum motor speed
Motor moment of inertia
Moment of inertia, ratio total to
Motor weight
Motor stator resistance, cold
Cable resistance (component of
the stator resistance)
Motor rotor resistance, cold
Motor stator inductance
Motor rotor leakage inductance
Motor magnetizing inductance
Current limit
Minimum speed
Operating Modes
Comments
If this value is not known, then a
"0" can also be entered. Using
this value, the stator leakage
inductance can be more
precisely calculated (p0356,
p0357).
Comments
This value is limited to a
maximum of 4 * p0305.
The value is pre-assigned with
1.5 * p0305 during
commissioning.
3-171