Foreword
Caution
!
S
The surface temperature of the motors can reach over +80 _C.
S
For this reason, temperature-sensitive parts (lines or electronic components,
for example) must not be placed on or attached to the motor.
S
When attaching the connecting cables, you must ensure that:
– They are not damaged
– They are not under tension
– They cannot come into contact with rotating parts.
Caution
S
As part of routine tests, SINAMICS devices with AC motors undergo a voltage
test in accordance with EN 50178. Before the voltage test is performed on the
electrical equipment of industrial machines to EN 60204-1, Section 19.4, all
connectors of SINAMICS equipment must be disconnected/unplugged to
prevent the equipment from being damaged.
S
Motors must be connected in accordance with the circuit diagram provided,
otherwise they could be destroyed.
Note
S
When operated in dry operating areas, SINAMICS equipment with three-phase
motors conforms to low-voltage Directive 73/23/EEC.
xii
© Siemens AG 2006 All Rights Reserved
SINAMICS S120 Function Manual, 03/2006 Edition