Siemens SINAMICS S120 Function Manual page 106

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Operating Modes
Servo control
Motor Module
p1953
p1952
Fig. 3-18
Equivalent circuit diagram for induction motor and cable
Motor Module
p1952
p1953
Fig. 3-19
Equivalent circuit diagram for synchronous motor and cable
Overview of important parameters (refer to the List Manual)
S r0047
Standstill measurement
S p1909
S p1910
Rotating measurement
S p1958
S p1959
S p1960
3-106
Series
Cable
inductance
p0353 [M]
p0352 [M]
L
R
var
cable
Series
Cable
inductance
p0353 [M]
p0352 [M]
L
var
Status identification
Motor data identification control word
Motor data identification routine, stationary (standstill)
Motor data identification ramp-up/ramp-down times
Rotating measurement configuration
Rotating measurement selection
Motor
p0350[M]
p0356 [M]
σ
R
L
S
S
p0360 [M]
p0350[M]
R
R
S
cable
© Siemens AG 2006 All Rights Reserved
SINAMICS S120 Function Manual, 03/2006 Edition
p0358 [M] p0354 [M]
R
R
R
L
M
Motor
p0356 [M]
Lσ S
~
p 0317 [M]
Mot kE