3.2.10
Current setpoint filter
Description
The two current setpoint filters connected in series can be parameterized as
follows:
S Low-pass 2nd order (PT2): –40dB/decade)
S General filter 2nd order
Band-stop and low-pass with reduction are converted to the parameters of the
general filter 2nd order via STARTER.
– Bandstop
– Low-pass with reduction by a constant value
The phase frequency curve is shown alongside the amplitude log frequency curve.
A phase shift results in a control system delay and should be kept to a minimum.
Overview of important parameters (refer to the List Manual)
S p1655
S p1666
Function diagram overview (refer to the List Manual)
S 6710
© Siemens AG 2006 All Rights Reserved
SINAMICS S120 Function Manual, 03/2006 Edition
CI: Current setpoint filter natural frequency tuning
Current setpoint filter 2 numerator damping
Current setpoint filter
Operating Modes
Vector control
3-147