Commissioning
5.1 The built-in Basic Operator Panel (BOP)
Button functions
Stops the inverter
Single press
Double press (< 2 s) or
long press ( > 3 s)
Starts the inverter
If the inverter is started in HAND / JOG mode, the inverter running icon (
Note:
This button is inactive if the inverter is configured for control from terminals (P0700 = 2, P1000 = 2) and
is in AUTO mode.
Multi-function button
Short press ( < 2 s)
Long press ( > 2 s)
Short press ( < 2 s)
Long press ( > 2 s)
Hand/Jog/Auto
+
Press to switch between different modes:
Note:
Jog mode is only available if the motor is stopped.
50
OFF1 stop reaction: the inverter brings the motor to a standstill in the ramp-
down time set in parameter P1121.
Note:
If configured to be an OFF1 stop, this button is inactive in AUTO mode.
OFF2 stop reaction: the inverter allows the motor to coast to a standstill
without using any ramp-down times.
Enters the parameter setting menu or moves to the next screen
•
Restarts the digit by digit editing on the selected item
•
Returns to the fault code display
•
If pressed twice in digit by digit editing, returns to the previous screen
•
without changing the item being edited
Returns to the status screen
•
Enters the setup menu
•
Switches between status values
•
Enters edit value mode or change to the next digit
•
Clears faults
•
Returns to the fault code display
•
Quick parameter number or value edit
•
Accesses fault information data
•
) displays.
SINAMICS V20 Inverter
Operating Instructions, 09/2014, A5E34559884