Siemens SINAMICS V20 Operating Instructions Manual page 193

Hide thumbs Also See for SINAMICS V20:
Table of Contents

Advertisement

Parameter
Function
[1]
[2]
Note:
Only one set of fault information is stored per block of instantaneous faults. r0955[0] corresponds to
r0947[0...7], r0955[1] corresponds to r0947[8...15] and r0955[2] corresponds to r0947[16...23].
r0956[0...2]
CO: DC-link voltage at
fault
Displays the DC link voltage when the first instantaneous fault occurs (see r0026).
Index:
[0]
[1]
[2]
Note:
Only one set of fault information is stored per block of instantaneous faults. r0956[0] corresponds to
r0947[0...7], r0956[1] corresponds to r0947[8...15] and r0956[2] corresponds to r0947[16...23].
r0957[0...2]
CO: Act. output current
at fault
Displays the output current RMS when the first instantaneous fault occurs (see r0027).
Index:
[0]
[1]
[2]
Note:
Only one set of fault information is stored per block of instantaneous faults. r0957[0] corresponds to
r0947[0...7], r0957[1] corresponds to r0947[8...15] and r0957[2] corresponds to r0947[16...23].
r0958[0...2]
CO: Act. output voltage
at fault
Displays the output voltage when the first instantaneous fault occurs (see r0025).
Index:
[0]
[1]
[2]
Note:
Only one set of fault information is stored per block of instantaneous faults. r0958[0] corresponds to
r0947[0...7], r0958[1] corresponds to r0947[8...15] and r0958[2] corresponds to r0947[16...23].
r0964[0...6]
Firmware version data
Firmware version data.
Index:
[0]
[1]
[2]
[3]
[4]
[5]
[6]
r0967
Control word 1
Displays control word 1. See r0054 for the bit field description.
r0968
Status word 1
Displays active status word of inverter (in binary) and can be used to diagnose which commands are ac-
tive. See r0052 for the bit field description.
SINAMICS V20 Inverter
Operating Instructions, 09/2014, A5E34559884
Range
Factory
Can be
default
changed
Recent trip - 1 Fault information
Recent trip - 2 Fault information
-
-
-
Recent trip - Fault information
Recent trip - 1 Fault information
Recent trip - 2 Fault information
-
-
-
Recent trip - Fault information
Recent trip - 1 Fault information
Recent trip - 2 Fault information
-
-
-
Recent trip - Fault information
Recent trip - 1 Fault information
Recent trip - 2 Fault information
-
-
-
Company (Siemens = 42)
Product type (V20 = 8001)
Firmware version
Firmware date (year)
Firmware date (day / month)
Number of inverter objects
Firmware version
-
-
-
-
-
-
Parameter list
7.2 Parameter list
Scaling
Data
Data
set
type
-
-
Float
-
-
Float
-
-
Float
-
-
U16
-
-
U16
-
-
U16
Acc.
Level
3
3
3
3
3
3
193