Siemens SINAMICS V20 Operating Instructions Manual page 242

Hide thumbs Also See for SINAMICS V20:
Table of Contents

Advertisement

Parameter list
7.2 Parameter list
Parameter
Function
Dependency:
This parameter is influenced by automatic calculations defined by P0340.
See P2181 for calculated default value.
Note:
The factory setting depends on rating data of Power Module and Motor.
P2186[0...2]
Lower torque threshold 1
[Nm]
Lower limit threshold value 1 for comparing actual torque.
Dependency:
See P2181 for calculated default value.
P2187[0...2]
Upper torque threshold 2
[Nm]
Upper limit threshold value 2 for comparing actual torque.
Dependency:
This parameter is influenced by automatic calculations defined by P0340.
See P2181 for calculated default value.
Note:
See P2185
P2188[0...2]
Lower torque threshold 2
[Nm]
Lower limit threshold value 2 for comparing actual torque.
Dependency:
See P2181 for calculated default value.
P2189[0...2]
Upper torque threshold 3
[Nm]
Upper limit threshold value 3 for comparing actual torque.
Dependency:
This parameter is influenced by automatic calculations defined by P0340.
See P2181 for calculated default value.
Note:
See P2185
P2190[0...2]
Lower torque threshold 3
[Nm]
Lower limit threshold value 3 for comparing actual torque.
Dependency:
See P2181 for calculated default value.
P2192[0...2]
Load monitoring delay
time [s]
P2192 defines a delay before warning / trip becomes active.
- It is used to eliminate events caused by transient conditions.
- It is used for both methods of fault detection.
r2197.0...12
CO / BO: Monitoring word
1
Monitoring word 1 which indicates the state of monitor functions. Each bit represents one monitor function.
Bit
00
01
02
03
04
05
06
242
Range
0.0 -
99999.0
0.0 -
99999.0
0.0 -
99999.0
0.0 -
99999.0
0.0 -
99999.0
0 - 65
-
Signal name
|f_act| <= P1080 (f_min)
|f_act| <= P2155 (f_1)
|f_act| > P2155 (f_1)
f_act >= zero
f_act >= setp. (f_set)
|f_act| <= P2167 (f_off)
|f_act| >= P1082 (f_max)
Factory
Can be
default
changed
0.0
U, T
Value in
U, T
r0333
0.0
U, T
Value in
U, T
r0333
0.0
U, T
10
U, T
-
-
Operating Instructions, 09/2014, A5E34559884
Scaling
Data
Data
set
type
-
DDS
Float
-
DDS
Float
-
DDS
Float
-
DDS
Float
-
DDS
Float
-
DDS
U16
-
-
U16
1 signal
0 signal
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
SINAMICS V20 Inverter
Acc.
Level
3
3
3
3
3
3
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents