Parameter list
7.2 Parameter list
Parameter
Function
Displays the motorized potentiometer setpoint before it passed the PID-MOP RFG.
P2247[0...2]
PID-MOP ramp-up time of
the RFG [s]
Sets the ramp-up time for the internal PID-MOP ramp-function generator. The setpoint is changed from
zero up to limit defined in P1082 within this time.
Notice:
Refer to: P2248, P1082
P2248[0...2]
PID-MOP ramp-down
time of the RFG [s]
Sets the ramp-down time for the internal PID-MOP ramp-function generator. The setpoint is changed from
limit defined in P1082 down to zero within this time.
Notice:
Refer to: P2247, P1082
r2250
CO: Output setpoint of
PID-MOP [%]
Displays output setpoint of motor potentiometer.
P2251
PID mode
Enables function of PID controller.
0
1
Dependency:
Active when PID loop is enabled (see P2200).
P2253[0...2]
CI: PID setpoint
Defines setpoint source for PID setpoint input. This parameter allows the user to select the source of the
PID setpoint. Normally, a digital setpoint is selected either using a fixed PID setpoint or an active setpoint.
P2254[0...2]
CI: PID trim source
Selects trim source for PID setpoint. This signal is multiplied by the trim gain and added to the PID set-
point.
Setting:
755
2224
2250
P2255
PID setpoint gain factor
Gain factor for PID setpoint. The PID setpoint input is multiplied by this gain factor to produce a suitable
ratio between setpoint and trim.
P2256
PID trim gain factor
Gain factor for PID trim. This gain factor scales the trim signal, which is added to the main PID setpoint.
P2257
Ramp-up time for PID
setpoint [s]
Sets the ramp-up time for the PID setpoint.
Dependency:
P2200 = 1 (PID control is enabled) disable normal ramp-up time (P1120). PID ramp time effective only on
PID setpoint and only active when PID setpoint is changed or when RUN command is given (when PID
setpoint uses this ramp to reach its value from 0 %).
248
Range
Factory
Can be
default
changed
0.00 -
10.00
U, T
1000.0
0.00 -
10.00
U, T
1000.0
-
-
-
0 - 1
0
T
PID as setpoint
PID as trim
0 -
0
U, T
429496729
5
0 -
0
U, T
429496729
5
Analog input 1
Fixed PI setpoint (see P2201 to P2207)
Active PI setpoint (see P2240)
0.00 -
100.00
U, T
100.00
0.00 -
100.00
U, T
100.00
0.00 -
1.00
U, T
650.00
Scaling
Data
set
-
DDS
-
DDS
PERCEN
-
T
-
-
4000H
CDS
4000H
CDS
-
-
-
-
-
-
SINAMICS V20 Inverter
Operating Instructions, 09/2014, A5E34559884
Data
Acc.
type
Level
Float
2
Float
2
Float
2
U16
3
U32
2
U32
3
Float
3
Float
3
Float
2