Siemens SINAMICS V20 Operating Instructions Manual page 159

Hide thumbs Also See for SINAMICS V20:
Table of Contents

Advertisement

Parameter
Function
03
04
05
06
08
09
13
15
Notice:
r0055 is identical to r2037 if USS is selected as command source via P0700 or P0719.
r0056.0...15
CO / BO: Status of
motor control
Displays status of motor control (in bit format), which can be used to diagnose inverter status.
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Notice:
The I-max controller (r0056 bit 13) will be activated when the actual output current (r0027) exceeds the
current limit in r0067.
r0066
CO: Actual output
frequency [Hz]
Displays actual output frequency in Hz. This value is available filtered (r0024) and unfiltered (r0066).
Note:
The output frequency is limited by the values entered in P1080 (minimum frequency) and P1082 (maxi-
mum frequency).
r0067
CO: Actual output
current limit [A]
SINAMICS V20 Inverter
Operating Instructions, 09/2014, A5E34559884
Range
Fixed frequency Bit 3
Inverter data set (DDS) Bit 0
Inverter data set (DDS) Bit 1
Quick stop disable
Enable PID
Enable DC brake
External fault 1
Command data set (CDS) Bit 1
-
Signal name
Init. control finished
Motor demagnetizing finished
Pulses enabled
Voltage soft start select
Motor excitation finished
Starting boost active
Acceleration boost active
Frequency is negative
Field weakening active
Volts setpoint limited
Slip frequency limited
f_out > f_max Freq. limited
Phase reversal selected
Imax controller active / torque limit reached
Vdc_max controller active
KIB (Vdc_min control) active
-
-
Factory
Can be
default
changed
-
-
-
-
-
-
Parameter list
7.2 Parameter list
Scaling
Data
Data
set
type
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
No
Yes
Yes
No
-
-
U16
1 signal
0 signal
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
-
-
Float
P2002
-
Float
Acc.
Level
3
3
3
159